0.6/1kV RFOU [P1], [P1/P8]
Substituted
1
1
1.0
1.0
5.1
0.2
6.2
1.0
8.4
120
0.6/1kV RFOU [P1], [P1/P8]
Substituted
1
1.5
1.0
1.0
5.4
0.2
6.5
1.1
8.9
135
0.6/1kV RFOU [P1], [P1/P8]
Substituted
1
2.5
1.0
1.0
5.8
0.2
6.9
1.1
9.3
150
0.6/1kV RFOU [P1], [P1/P8]
Substituted
1
4
1.0
1.0
6.4
0.2
7.5
1.1
9.9
180
0.6/1kV RFOU [P1], [P1/P8]
Substituted
1
6
1.0
1.0
6.9
0.2
8.0
1.1
10.4
205
0.6/1kV RFOU [P1], [P1/P8]
Substituted
1
10
1.0
1.0
7.9
0.2
9.0
1.2
11.6
270
0.6/1kV RFOU [P1], [P1/P8]
Substituted
1
16
1.0
1.0
8.9
0.2
10.0
1.2
12.6
350
0.6/1kV RFOU [P1], [P1/P8]
Substituted
1
25
1.2
1.0
10.7
0.3
12.3
1.3
15.1
535
0.6/1kV RFOU [P1], [P1/P8]
Substituted
1
35
1.2
1.0
11.9
0.3
13.5
1.3
16.3
655
0.6/1kV RFOU [P1], [P1/P8]
Substituted
1
50
1.4
1.0
13.6
0.3
15.2
1.4
18.2
825
0.6/1kV RFOU [P1], [P1/P8]
Substituted
1
70
1.4
1.0
15.5
0.3
17.1
1.5
20.3
1080
0.6/1kV RFOU [P1], [P1/P8]
Substituted
1
95
1.6
1.0
17.8
0.3
19.4
1.6
22.8
1410
0.6/1kV RFOU [P1], [P1/P8]
Substituted
1
120
1.6
1.0
19.4
0.3
21.0
1.6
24.4
1685
0.6/1kV RFOU [P1], [P1/P8]
Substituted
1
150
1.8
1.0
21.4
0.3
23.0
1.7
26.6
2020
0.6/1kV RFOU [P1], [P1/P8]
Substituted
1
185
2.0
1.0
23.6
0.3
25.2
1.8
29.0
2455
0.6/1kV RFOU [P1], [P1/P8]
Substituted
1
240
2.2
1.2
27.1
0.3
28.7
1.9
32.7
3155
0.6/1kV RFOU [P1], [P1/P8]
Substituted
1
300
2.4
1.2
29.9
0.3
31.5
2.1
35.9
3865
0.6/1kV RFOU [P1], [P1/P8]
Substituted
2
1
1.0
1.0
8.6
0.2
9.7
1.2
12.3
245
0.6/1kV RFOU [P1], [P1/P8]
Substituted
2
1.5
1.0
1.0
9.2
0.2
10.3
1.2
12.9
270
0.6/1kV RFOU [P1], [P1/P8]
Substituted
2
2.5
1.0
1.0
10
0.2
11.1
1.2
13.7
320
0.6/1kV RFOU [P1], [P1/P8]
Substituted
2
4
1.0
1.0
11.2
0.3
12.8
1.3
15.6
440
0.6/1kV RFOU [P1], [P1/P8]
Substituted
2
6
1.0
1.0
12.2
0.3
13.8
1.4
16.8
525
0.6/1kV RFOU [P1], [P1/P8]
Substituted
2
10
1.0
1.0
14.2
0.3
15.8
1.4
18.8
685
0.6/1kV RFOU [P1], [P1/P8]
Substituted
2
16
1.0
1.0
16.2
0.3
17.8
1.5
21.0
895
0.6/1kV RFOU [P1], [P1/P8]
Substituted
2
25
1.2
1.0
19.8
0.3
21.4
1.7
25.0
1295
0.6/1kV RFOU [P1], [P1/P8]
Substituted
2
35
1.2
1.0
22.2
0.3
23.8
1.8
27.6
1630
0.6/1kV RFOU [P1], [P1/P8]
Substituted
2
50
1.4
1.0
25.6
0.3
27.2
1.9
31.2
2085
0.6/1kV RFOU [P1], [P1/P8]
Substituted
2
70
1.4
1.2
29.8
0.3
31.4
2.1
35.8
2795
0.6/1kV RFOU [P1], [P1/P8]
Substituted
2
95
1.6
1.2
34.4
0.4
36.4
2.3
41.2
3780
0.6/1kV RFOU [P1], [P1/P8]
Substituted
2
120
1.6
1.4
37.8
0.4
39.8
2.4
44.8
4560
0.6/1kV RFOU [P1], [P1/P8]
Substituted
2
150
1.8
1.4
41.8
0.4
43.8
2.6
49.2
5500
0.6/1kV RFOU [P1], [P1/P8]
Substituted
2
185
2.0
1.4
46.2
0.4
48.2
2.7
53.8
6675
0.6/1kV RFOU [P1], [P1/P8]
Substituted
2
240
2.2
1.6
52.8
0.4
54.8
3.0
61.0
8605
0.6/1kV RFOU [P1], [P1/P8]
Substituted
2
300
2.4
1.6
58.4
0.4
60.4
3.2
67.0
10510
0.6/1kV RFOU [P1], [P1/P8]
Substituted
3
1
1.0
1.0
9.1
0.2
10.2
1.2
12.7
280
0.6/1kV RFOU [P1], [P1/P8]
Substituted
3
1.5
1.0
1.0
9.8
0.2
10.9
1.2
13.4
320
0.6/1kV RFOU [P1], [P1/P8]
Substituted
3
2.5
1.0
1.0
10.7
0.3
12.3
1.3
15.0
420
0.6/1kV RFOU [P1], [P1/P8]
Substituted
3
4
1.0
1.0
11.9
0.3
13.5
1.3
16.2
510
0.6/1kV RFOU [P1], [P1/P8]
Substituted
3
6
1.0
1.0
13
0.3
14.6
1.4
17.5
610
0.6/1kV RFOU [P1], [P1/P8]
Substituted
3
10
1.0
1.0
15.2
0.3
16.8
1.5
19.9
830
0.6/1kV RFOU [P1], [P1/P8]
Substituted
3
16
1.0
1.0
17.3
0.3
18.9
1.6
22.2
1100
0.6/1kV RFOU [P1], [P1/P8]
Substituted
3
25
1.2
1.0
21
0.3
22.8
1.7
26.1
1560
0.6/1kV RFOU [P1], [P1/P8]
Substituted
3
35
1.2
1.0
24
0.3
25.4
1.8
29.3
2000
0.6/1kV RFOU [P1], [P1/P8]
Substituted
3
50
1.4
1.2
27.8
0.3
29.5
2.0
33.5
2620
0.6/1kV RFOU [P1], [P1/P8]
Substituted
3
70
1.4
1.2
31.9
0.4
34.0
2.2
38.4
3580
0.6/1kV RFOU [P1], [P1/P8]
Substituted
3
95
1.6
1.2
36.8
0.4
38.9
2.3
43.5
4700
0.6/1kV RFOU [P1], [P1/P8]
Substituted
3
120
1.6
1.4
40.6
0.4
42.6
2.5
47.7
5750
0.6/1kV RFOU [P1], [P1/P8]
Substituted
3
150
1.8
1.4
44.9
0.4
46.9
2.7
52.4
6960
0.6/1kV RFOU [P1], [P1/P8]
Substituted
3
185
2.0
1.6
50
0.4
52.0
2.9
57.9
8560
0.6/1kV RFOU [P1], [P1/P8]
Substituted
3
240
2.2
1.6
56.7
0.4
58.7
3.1
65.0
10940
0.6/1kV RFOU [P1], [P1/P8]
Substituted
3
300
2.4
1.8
63
0.4
64.9
3.4
71.9
13490
0.6/1kV RFOU [P1], [P1/P8]
Substituted
4
1
1.0
1.0
10
0.2
11.1
1.2
13.6
320
0.6/1kV RFOU [P1], [P1/P8]
Substituted
4
1.5
1.0
1.0
10.8
0.3
12.4
1.3
15.1
410
0.6/1kV RFOU [P1], [P1/P8]
Substituted
4
2.5
1.0
1.0
11.7
0.3
13.3
1.3
16.0
480
0.6/1kV RFOU [P1], [P1/P8]
Substituted
4
4
1.0
1.0
13.2
0.3
14.8
1.4
17.7
610
0.6/1kV RFOU [P1], [P1/P8]
Substituted
4
6
1.0
1.0
14.4
0.3
16.0
1.4
18.9
730
0.6/1kV RFOU [P1], [P1/P8]
Substituted
4
10
1.0
1.0
16.8
0.3
18.4
1.5
21.5
990
0.6/1kV RFOU [P1], [P1/P8]
Substituted
4
16
1.0
1.0
19.2
0.3
20.8
1.6
24.1
1330
0.6/1kV RFOU [P1], [P1/P8]
Substituted
4
25
1.2
1.0
23.3
0.3
25.2
1.8
28.6
1920
0.6/1kV RFOU [P1], [P1/P8]
Substituted
4
35
1.2
1.2
27
0.3
28.1
1.9
32.5
2500
0.6/1kV RFOU [P1], [P1/P8]
Substituted
4
50
1.4
1.2
30.9
0.4
33.0
2.1
37.2
3340
0.6/1kV RFOU [P1], [P1/P8]
Substituted
4
70
1.4
1.2
35.5
0.4
37.6
2.3
42.2
4440
0.6/1kV RFOU [P1], [P1/P8]
Substituted
4
95
1.6
1.4
41.3
0.4
43.3
2.5
48.4
5930
0.6/1kV RFOU [P1], [P1/P8]
Substituted
4
120
1.6
1.4
45.2
0.4
47.2
2.7
52.7
7210
0.6/1kV RFOU [P1], [P1/P8]
Substituted
4
150
1.8
1.6
50.4
0.4
52.4
2.9
58.3
8800
0.6/1kV RFOU [P1], [P1/P8]
Substituted
4
185
2.0
1.6
55.7
0.4
57.7
3.1
64.0
10760
0.6/1kV RFOU [P1], [P1/P8]
Substituted
4
240
2.2
1.8
63.5
0.4
65.4
3.4
72.4
13890
0.6/1kV RFOU [P1], [P1/P8]
Substituted
4
300
2.4
1.8
70.2
0.4
72.2
3.7
79.8
17405